How true pro’s measure TECH 700 DA User manual
en Contents Section • 1. Intended use 2 Page 3 • 2. Components of the unit 3 • 3. Insert batteries/Battery replacement 4 • 4. Commissioning 4 • 5. Automatic switch-off time 4 • 6. Angle finder 5 • 7. Spirit level 5 • 8. Bevel gauge 5 • 9. Reference function 6 • 10. Lighting 7 • 11. HOLD function 7 • 12. Angle halving 8 • 13. Calibration of zero position 8 • 14.
en 1. Intended use The STABILA TECH 700 DA is an electronic angle finder with digital display for quickly and easily measuring angles. Together with the vials, the angle finder can also be used as a spirit level. On/Off If you still have questions after reading through the operating instructions, you can obtain advice by telephone: +49 63 46 3 09 0 1.800.869.7460 U.S.
en 3. Insert batteries / Battery replacement Unscrew battery compartment lid on front, insert new batteries according to symbol in battery compartment. Suitable rechargeable batteries can also be used. LCD: low battery charge - insert new battery 1. 2x 1.5V alkaline AA, LR6, Mignon MN 1500 2. Dispose of used batteries at suitable collection points - not with household waste. Do not leave in unit! Remove the batteries if you do not intend to use the unit for some time! 4.
en 6. Angle finder The angle finder displays the angle currently set between the arm and body. Angle measurements can be taken between 0° and 270°. 0°... 270° 7. Spirit level 0,5 mm/m 0,029° The angle finder with 2 measuring surfaces is also a fully functional spirit level for horizontal and vertical measurements to level construction elements. High-quality STABILA technology makes the vials suitable for measurements: (1) in the normal position (2) in the reverse position 0,75 mm/m 0,043° 8.
en 9. Reference function 1x The REF button can be used to select any set angle as 0° reference. The angle details now displayed relate to this reference angle. The next time the arm is rotated, only the newly set angle is displayed. The display flashes in this setting. The REF symbol indicates this function setting. 1x The original reference angle value is displayed for 2 seconds by briefly pressing the REF button.
en 10. Lighting 1x Repeatedly pressing the "Lighting" button switches the display lighting on, to half luminance or off. 1x 1x 11. HOLD function 1x The current measurement can be saved by pressing the HOLD button. The measurement is displayed continuously. In this setting, the display flashes and the HOLD symbol is displayed. This function can be used in combination with the reference function. The saved measurement is deleted by again pressing the HOLD button or switching the unit off.
en 12. Angle halving The current measurement is halved by pressing the "Angle halving" button. The measurement is displayed continuously. In this setting, the display flashes and the "Angle halving" symbol is displayed. 1x The value is deleted by again pressing the "Angle halving" button or switching the unit off. 13. Calibration of zero position Display value ≠ 0.0° 1x 3 sec During use, instances may arise when the display does not show 0.0° when the arm is swivelled all the way in.
en 14. Technical Data Accuracy of electronics module: Angle measurement: ± 0.1° Accuracy of spirit level: in normal position: in reverse position: 0.5 mm / m = 0.029° 0.75 mm / m = 0.043° Measuring range: 0° - 270° Batteries : Operating life : Operating temperature range: Storage temperature range: Protection class: 2 x 1.5 V alkaline, size Mignon, AA, LR6 ≥ 150 hours -10 °C to +50 °C / 14°F to 122°F -20 °C to +65 °C / -4°F to 149°F IP 54 Subject to technical modifications.
Europe Middle and South America Australia Asia Africa USA Canada STABILA Messgeräte Gustav Ullrich GmbH STABILA Inc. P.O. Box 13 40 / D-76851 Annweiler Landauer Str. 45 / D-76855 Annweiler 332 Industrial Drive South Elgin , IL 60177 + 49 63 46 309 - 0 info@de.stabila.com 800-869-7460 custservice@Stabila.com www.stabila.