8. Technical data
Accuracy:
0° / 90° / 180° / 270° : ± 0,05°
In intermediate areas ± 0,2°
Batteries: 2 x 1,5 V alkaline,
Mignon, AA, LR6, MN1500
Battery life: ≥ 150 hours
Operating temperature range: -10 °C to +5o °C
14 °F to 122 °F
Storage temperature range: -20 °C to +65 °C
-4 °F to 149 °F
Housing material: Aluminium / PC-ABS
Dimensions: ca. 70 x 32 x 175 mm
Weight: 440 g
Protection class: IP 65