7.3 Adjusting the sensor
The sensor must be adjusted if the temperature or Cal.
symbols are shown in the display.
A:
All 4 planes are adjusted during the sensor adjustment.
B:
The sensor can only be adjusted if the two black bars
appear on the display (in the range of 0° and 90°).
C:
CAL and the planes still to be adjusted flash alternately
while the sensor is being adjusted for the respective plane.
D:
Planes that have not been adjusted flash in the display.
Successfully adjusted planes are permanently indicated
in the display.