Product Manual
Table Of Contents
- 1. Intended use
- 2. Components of the unit
- 3. Display elements
- 4. Commissioning
- 4.1 Power supply - Charging the Li-ion rechargeable battery
- 4.2 M12 socket pin assignment
- 4.3 Connection cable
- 4.4 Switching the unit on
- 5. Functions
- 5.1 Visual guidance
- 5.2 Acoustic guidance
- 5.3 Automatic display inversion
- 5.4 Setting the "MODE" unit of measurement
- 5.5 Locking the measurement with "HOLD"
- 5.6 Freely selectable zero position "REF"
- 6. "FUNC" button settings
- 7. Checking the measuring tool
- 7.1 Accuracy check
- 7.2 Calibration -– Adjustment
- 7.3 Calibration
- 7.4 Adjusting the sensor
- 7.5 Error messages
- 8. Data transfer
- 8.1 Querying the measurement
- 8.2 Changing the bus address
- 8.3 Error codes
- 8.4 Auto mode
- 8.5 Print mode
- 9. STABILA Analytics evaluation software (optional)
- 10. Technical data
TECH 1000 DP
9
en
5.2 Acoustic guidance
The acoustic guidance is selected via the "FUNC" button.
The tone sequence speeds up as the 0°, 90°, 180° and
270° positions are approached in a range of +/- 2°.
A change in the pitch indicates that these positions have
been exceeded.
A continuous signal tone confirms the precise point at
which 0°, 90°,180° and 270° are reached.
This function is not active in interface mode.
5.3 Automatic display inversion
The display is inverted for overhead measurements so that
it is always legible.