Product Manual

TECH 1000 DP
23
en
10. Technical data
Accuracy:
0° / 90° / 180° / 270°: ± 0.05°
In intermediate areas: ± 0.1°
Data output standard: RS485
Power supply: Li-ion polymer rechargeable battery 2400 mAh
Battery life: ≥ 150 hours
External mains adapter:
Charging temperature range: 0 °C to +40 °C
Operating temperature range: -10 °C to +50 °C
Storage temperature range: -20 °C to +65 °C
Housingmaterial: Aluminium / PC-ABS
Dimensions: approx. 70 x 32 x 175 mm
Weight: 450 g
Protection class: IP 65 with closed connection sockets
Subject to technical modifications.
STABILA Analytics provides communication between a Windows PC and the TECH 1000 DP
digital protractor made by the company STABILA Messgeräte GmbH. The TECH 1000 DP is
connected to the computer via the data cable provided.
The Analytics evaluation software can only be connected with a baud rate of 9600 Bd.
Installation requirements:
TECH 1000 DP with the data cable provided (RS485 to USB)
PC with operating system Microsoft Windows XP SP3, Windows 7, Windows 8 or Windows 10
At least Windows installer version 4.5.6001.22159
• .NetFramework 4
9. STABILA Analytics evaluation soware (optional)