TECH 1000 DP
18
en
Adj.
7.5 Error messages
The sensor must be adjusted if the "temperature" or "ADJ"
symbols are shown in the display.
Display: Error
The measuring unit must not be moved or subjected to vi-
brations during the calibration/sensor adjustment. This can
lead to measurement errors.
Display: - - - -
Measuring unit inclination around longitudinal axis > 10°
Display: mains connection/battery symbol flashes
Temperature too high or too low to operate the rechargea-
ble battery
Display: mains connection/battery symbol flashes quickly
Charging voltage too high or too low
Display: only the lightning symbol flashes quickly
Rechargeable battery is faulty