Product Manual

TECH 1000 DP
14
en
7.3 Calibration
Step 1: Once "Calibration" has been selected with the
"CAL/ADJ" button, confirm by pressing "Enter".
Display: CAL2P
Step 2:
Place the unit with the lower measuring sole on as horizontal
a surface as possible (e.g. a table) with the display side
facing the user. Calibration is started by pressing the
"CAL/ADJ" button. "CAL" flashes in the display.
Display: CAL2
Calibration step 2 successfully completed
Step 3:
Turn the unit by 180° in the same position.
Step 4:
The rear of the unit is now facing the user. The second
calibration is started by pressing the "CAL/ADJ" button.
"CAL" flashes in the display.
"rdy" display: Calibration completed successfully!