Product Manual
Table Of Contents
- 1. Intended use
- 2. Components of the unit
- 3. Display elements
- 4. Commissioning
- 4.1 Power supply - Charging the Li-ion rechargeable battery
- 4.2 M12 socket pin assignment
- 4.3 Connection cable
- 4.4 Switching the unit on
- 5. Functions
- 5.1 Visual guidance
- 5.2 Acoustic guidance
- 5.3 Automatic display inversion
- 5.4 Setting the "MODE" unit of measurement
- 5.5 Locking the measurement with "HOLD"
- 5.6 Freely selectable zero position "REF"
- 6. "FUNC" button settings
- 7. Checking the measuring tool
- 7.1 Accuracy check
- 7.2 Calibration -– Adjustment
- 7.3 Calibration
- 7.4 Adjusting the sensor
- 7.5 Error messages
- 8. Data transfer
- 8.1 Querying the measurement
- 8.2 Changing the bus address
- 8.3 Error codes
- 8.4 Auto mode
- 8.5 Print mode
- 9. STABILA Analytics evaluation software (optional)
- 10. Technical data
TECH 1000 DP
11
en
20.05°
= 25.05°
+ 5°
> 3 sec
= 20.05°
25.05°
Ref
3 sec
5.6 Freely selectable zero position "REF"
The "REF" button can be used to select any set angle as
0° reference. The angle details now displayed relate to this
reference angle. The displayed valueflashes with this setting.
A:
The reference angle value is displayed for 3 seconds by
briefly pressing the "REF" button.
B:
The reference angle is deleted by:
• Pressing and holding (≥ 3 sec) the "REF" button
If the keylock is active, this must be disabled first.
• Switching off
• The automatic switch-off function
The zero position then refers back to the original setting.
The alignment selected for the digital
protractor must not be changed during the
reference function, as this could lead to a
display error.
A
B
Ref
Ref
Ref
Ref
20.05°
Ref