TECH 1000 DP en Contents Section Page • 1. Intended use 3 • 2. Components of the unit 4 • 3. Display elements 5 • • • • • 4. 4.1 4.2 4.3 4.4 Commissioning Power supply - Charging the Li-ion rechargeable battery M12 socket pin assignment Connection cable Switching the unit on 6 6 6 7 7 • • • • • • • 5. 5.1 5.2 5.3 5.4 5.5 5.
TECH 1000 DP en 1. Intended use Congratulations on the purchase of your STABILA measuring tool. The STABILA TECH 1000 DP is a digital measuring tool for measuring inclinations.
en TECH 1000 DP 2. Components of the unit (1) Display (2) Mains adapter connection, M12 socket (3) Rare-earth magnet (4) T-groove profile for securing with M4 groove stones, e.g.
TECH 1000 DP en 5 3. Display elements (14) Acoustic guidance: activated (15) See chapter 7.4 (16) Keylock: activated (17) Data traffic (18) See chapter 4.1 (19) Units of measurement: °, %, mm/m, in/ft (20) See chapter 7.
en TECH 1000 DP 4. Commissioning 4.1 Power supply - Charging the Li-ion rechargeable battery The Li-ion rechargeable battery is charged using the mains adapter provided. Alternatively, the battery can be charged using the USB connection cable provided, as well as the M12 RS485 connection. The charging time depends on the maximum charging current of the source. Remaining connected to the mains adapter for a long period of time will not damage the Li-ion rechargeable battery.
en TECH 1000 DP 4.3 Connection cable Pin assignment for the enclosed connection cable to the M12 socket 4.4 Switching the unit on Adj. After switching on with the "ON/OFF" button, an automatic test is carried out. All the display's segments are shown. data Ref Hold After the end of the test, the version number S x.xx of the software is briefly displayed and the automatic switch-off time (Auto OFF) is shown. 9600 Bd = standard An acoustic signal indicates that the unit is ready for operation.
en TECH 1000 DP 5. Functions 5.1 Visual guidance Triangles representing the inclination indicate the position of the digital protractor in relation to the horizontal or vertical axis. The 2 "centre display" bars indicate the precise position at which the vertical or horizontal axis is reached. 90° Display showing direction of inclination 0.01° - 45.00° 270.01° - 315.00° 45.00 ° - 89.99° 135.00° - 179.99° 225.00° - 269.99° 315.00° - 359.99° 90.01° - 135.00° 180.01° - 225.00° 0° 8 0.00° 90.00° 180.
TECH 1000 DP en 5.2 Acoustic guidance The acoustic guidance is selected via the "FUNC" button. The tone sequence speeds up as the 0°, 90°, 180° and 270° positions are approached in a range of +/- 2°. A change in the pitch indicates that these positions have been exceeded. A continuous signal tone confirms the precise point at which 0°, 90°,180° and 270° are reached. This function is not active in interface mode. 5.
en TECH 1000 DP ° 0° 359.99° The unit of measurement is set by pressing the "MODE" button several times. ° 0° 359.9° 0% 5.4 Setting the "MODE" unit of measurement 100% 0% 1000 mm/m 0 mm/m 0 in/ft ° Precise Display in 0.01° increments ° Rough Display in 0.1° increments % Display in 0.1% increments mm/m Display in 1 mm/m increments in/ft Display in 0.01 in/ft increments The set unit of measurement is retained after the unit is switched off. 12 in/ft in/ft 0 in/ft 5.
en TECH 1000 DP 5.6 Freely selectable zero position "REF" The "REF" button can be used to select any set angle as 0° reference. The angle details now displayed relate to this reference angle. The displayed valueflashes with this setting. 20.05° = 20.05° Ref A A: The reference angle value is displayed for 3 seconds by briefly pressing the "REF" button. = 25.05° Ref Ref 20.05° + 5° Ref Ref > 3 sec 25.05° 11 The zero position then refers back to the original setting.
en TECH 1000 DP 6. "FUNC" button settings The user can switch between the different setting options by repeatedly pressing the "FUNC" button. While the display is flashing, the selected function can be confirmed with the "ENTER" button. If no button is pressed, the "FUNC" menu closes after a short time. 6.1. Lighting 6.2 Acoustic guidance The "ON/OFF", "FUNC" and "ENTER" buttons are always active. 6.3 Keylock 6.4 STABILA internal information data Adj. Ref 6.
en TECH 1000 DP 7. Checking the measuring tool 7.1 Accuracy check 1 To prevent measuring errors, the accuracy of the measuring tool must be checked at regular intervals; for example, each time before beginning work, or after a heavy impact or extreme fluctuations in temperature. Step 1: Place the unit with the lower measuring sole on as horizontal a surface as possible (e.g. a table) with the display side facing the user. Determine the measurement. 2 Step 2: Turn the unit by 180° in the same position.
en TECH 1000 DP 1 7.3 Calibration Step 1: Once "Calibration" has been selected with the "CAL/ADJ" button, confirm by pressing "Enter". Display: CAL2P 2 Step 2: Place the unit with the lower measuring sole on as horizontal a surface as possible (e.g. a table) with the display side facing the user. Calibration is started by pressing the "CAL/ADJ" button. "CAL" flashes in the display. 3 Display: CAL2 Calibration step 2 successfully completed Step 3: Turn the unit by 180° in the same position.
en TECH 1000 DP The sensor must be adjusted if the "temperature" or "Adj." symbols are shown in the display. Adj. A 2 7.4 Adjusting the sensor A: All 4 planes are adjusted during the sensor adjustment. 3 1 B B: The sensor can only be adjusted if the two black bars appear on the display (in the range of 0°, 90°, 180° and 270°). C C: "ADJ" flashes during sensor adjustment of the respective plane. D D: Planes that have not been adjusted are not displayed.
TECH 1000 DP en 7.4 Adjusting the sensor 1 Step 1: Once "Sensor adjustment" has been selected with the "CAL/ADJ" button, confirm by pressing "Enter". Display: ADJ4P Step 2: Hold the unit in plane 1. 2 Press the "CAL/ADJ" buttons. 1 3 If the plane has been adjusted successfully, it is displayed permanently. 2 Step 3: Turn the unit by 90° to plane 2. Press the "CAL/ADJ" button. If the plane has been adjusted successfully, it is displayed permanently.
TECH 1000 DP en 7.4 Adjusting the sensor 4 Step 4: Turn the unit by 90° to plane 3. 3 Press the "CAL/ADJ" button. If the plane has been adjusted successfully, it is displayed permanently. 5 Step 5: Turn the unit by 90° to plane 4. Press the "CAL/ADJ" button.
en TECH 1000 DP 7.5 Error messages The sensor must be adjusted if the "temperature" or "ADJ" symbols are shown in the display. Adj. Display: Error The measuring unit must not be moved or subjected to vibrations during the calibration/sensor adjustment. This can lead to measurement errors.
en TECH 1000 DP 8. Data transfer Multiple-participant mode: This mode enables multiple participants with different unit addresses but the same baud rate to connect to the MODBUS. protocol The transmission protocol is configured in accordance with the MODBUS standard. Characterformat: 1 start bit, 8 data bits, 2 stop bits, no parity Baud rate: Default setting: 9600 Bd Possible: 1200 Bd ... 19,200 Bd Idle period: at least 3.
en TECH 1000 DP 8.1 Querying the measurement Structure of the read command function 03 h ]) Example: querying the current angle ( register Structure of the response function 03 h Example: response at 45.
en TECH 1000 DP 8.2 Changing the bus address Structure of the write command function 06 h Example: changing address to 16 d 20 06 h h 10 h 04 h 00 h 10 h CB 86 h h Structure of the response function 06 h Example: changing address to 16 d 20 06 h h 10 h 04 h 00 h 10 h CB 86 h 8.3 Error codes An incorrect query is acknowledged with 8X h in the function code (second byte).
en TECH 1000 DP 8.4 Auto mode AUTO MODE: A measurement is transmitted immediately after each query. Example: If the inclination of the measuring unit in the longitudinal axis is greater than 10° during the measurement, the TECH 1000 DP supplies the value FFFF h ( 65535 d ). data 8.5 Print mode PRINT MODE: A query is sent from the PC to the measuring unit. If the "PRINT" button has not yet been pressed, the TECH 1000 DP supplies the value CCCC h ( 52428 d ).
en TECH 1000 DP 9. STABILA Analytics evaluation software (optional) STABILA Analytics provides communication between a Windows PC and the TECH 1000 DP digital protractor made by the company STABILA Messgeräte GmbH. The TECH 1000 DP is connected to the computer via the data cable provided. The Analytics evaluation software can only be connected with a baud rate of 9600 Bd.