GB Operating instructions The STABILA REC-120 Line is a simple-to-use receiver for the rapid capture of laser lines. The STABILA REC-120 Line can only receive pulse modulated laser beams. The receiver will not work with rotation lasers. We have endeavoured to explain the unit's handling and functioning in as clear and comprehensible manner as possible.
Getting started 1 Press the ON/OFF button (1). An audio signal and a short flash from the display will confirm, that the instrument is switched on. Press the ON/OFF button (1) quickly once to switch the instrument off. If the instrument is not used, it will automatically switch itself off after 30 minutes. Display 9 display steps indicate the divergence from the centre of the laser line. The central bar indicates the “in line” position of the REC 210 Line.
Measuring modes Construction mode The construction mode is active each time the instrument is switched on. Construction mode display The icons appear permanently Construction mode accuracy Fine Super-fine ± 0,50 mm ± 1,0 mm Medium ± 2,0 mm Wide ± 3,0 mm (c) Industrial mode The more sensitive industrial mode has a tolerance of ± 0.00mm in the “in line” position. Exact centre display ± 0,00 mm The instrument must first be switched off.
Replacing the batteries Anzeige Full: Batteries OK Half: Initial Warning Empty: Approximately 30 Minutes Remaining Flashing: Change Batteries! Slide the battery cover (8) in the direction of the arrow and insert new batteries in accordance with the symbols in the battery compartment. 2 x 1,5V Mignon cells Alkaline, Size AA, LR6 Mignon AA LR6 Remove the batteries if the unit will not be used for a long period ! Battery compartment cover. Water-tight.
Care and maintenance Cleaning: Please do not remove dust and dirt from the receiving or display window by using dry cloths or abrasive materials as this procedure scratches the windows. A soft cloth and mild soap and water are effective. The unit may be submerged under water or sprayed with a low pressure hose if necessary. Do not use any other fluids other than water or glass- cleaner, as they may attack polymer components. Prohibited Uses - Operation without instruction.
Technical data Working Radius: up to 110 m, Laser dependent 0m ~3 < 110m ~3 0m Accuracy Construction mode Super-Fine: Fine: Medium: Wide: Industrial - mode Zero: Detectable Spectrum: Beeper Volumes: Batteries: LCD Backlighting: Operating life: Automatic Shut Off: Operating temperature range: Storage temperature range: ± 0,50 mm ± 1,0 mm ± 2,0 mm ± 3,0 mm ± 0,0 mm 635 nm Loud: ~ 103 dBA Low: ~ 75 dBA 2 x 1,5V Mignon cells Alkaline , Size AA,LR 6 Yes (LCD symbol) 50 hours 30 minutes -20°C to +60°C -40°C to