SDS

NotestoPhysician
Alltreatmentsshouldbebasedonobservedsignsandsymptomsofdistressinthe
patient.Considerationshouldbegiventothepossibilitythatoverexposuretomaterials
otherthanthisproductmayhaveoccurred.
Section5:Fire
FightingMeasures
Extinguishingmedia
SuitableExtinguishingMedia
Usecarbondioxide,drychemical,foamand/orwaterfog.
UnsuitableExtinguishing
Media
Nodataavailable
Specialhazardsarisingfromthesubstanceormixture
UnusualFireandExplosion
Hazards
Containersmayexplodewhenheated.
Vaporexplosionhazardindoors,outdoorsorinsewers.
Combustiblematerial:mayburnbutdoesnotignitereadily.
Manyliquidsarelighterthanwater.
Mostvaporsareheavierthanair.Theywillspreadalonggroundandcollectinlowor
confinedareas(sewers,basements,tanks).
Runofftosewermaycreatefireorexplosionhazard.
Vaporsmayformexplosivemixtureswithair.
Vaporsmaytraveltosourceofignitionandflashback.
Watermaycausefrothing.
HazardousCombustion
Products
Nodataavailable
Adviceforfirefighters
Structuralfirefighters'protectiveclothingwillonlyprovidelimitedprotection.
Wearpositivepressureself
containedbreathingapparatus(SCBA).
Movecontainersfromfireareaifyoucandoitwithoutrisk.
LARGEFIRES:Coolcontainerswithfloodingquantitiesofwateruntilwellafterfireis
out.
Section6
AccidentalReleaseMeasures
Personalprecautions,protectiveequipmentandemergencyprocedures
PersonalPrecautions
Donotwalkthroughspilledmaterial.UseappropriatePersonalProtectiveEquipment
(PPE)Donottouchdamagedcontainersorspilledmaterialunlesswearingappropriate
protectiveclothing.
EmergencyProcedures
Asanimmediateprecautionarymeasure,isolatespillorleakareaforatleast50
meters(150feet)inalldirections.Iftank,railcarortanktruckisinvolvedinafire,
ISOLATEfor800meters(1/2mile)inalldirections;also,considerinitialevacuationfor
800meters(1/2mile)inalldirections.LARGESPILL:Considerinitialdownwind
evacuationforatleast300meters(1000feet)ELIMINATEallignitionsources(no
smoking,flares,sparksorflamesinimmediatearea).Keepunauthorizedpersonnel
away.Stayupwind.Keepoutoflowareas.Ventilateclosedspacesbeforeentering.
Environmentalprecautions
Prevententryintowaterways,sewers,basementsorconfinedareas.
Methodsandmaterialforcontainmentandcleaningup
Containment/Clean
up
Measures
Stopleakifyoucandoitwithoutrisk.
Absorborcoverwithdryearth,sandorothernon
combustiblematerialandtransferto
containers.
Usecleannon
sparkingtoolstocollectabsorbedmaterial.
Avaporsuppressingfoammaybeusedtoreducevapors.
Allequipmentusedwhenhandlingtheproductmustbegrounded.
LARGESPILLS:Dikefaraheadofliquidspillforlaterdisposal.
LARGESPILLS:Waterspraymayreducevapor;butmaynotpreventignitionin
closedspaces.
StaBil® Fuel Stabilizer – MarineStaBil® Fuel Stabilizer – MarineStaBil® Fuel Stabilizer – MarineStaBil® Fuel Stabilizer – Marine
Preparation Date: 09/September/2015Preparation Date: 09/September/2015Preparation Date: 09/September/2015Preparation Date: 09/September/2015
Revision Date: 17/September/2015Revision Date: 17/September/2015Revision Date: 17/September/2015Revision Date: 17/September/2015
Format: GHS Language: English (US)Format: GHS Language: English (US)Format: GHS Language: English (US)Format: GHS Language: English (US)
OSHA HCS 2012OSHA HCS 2012OSHA HCS 2012OSHA HCS 2012
Page 4 of 13Page 4 of 13Page 4 of 13Page 4 of 13