Datasheet

Electrical specifications VND600SP-E
8/27 Doc ID 10876 Rev 4
2.3 Electrical characteristics
Values specified in this section are for 8 V < V
CC
< 36 V;
-40 °C < T
j
< 150 °C, unless
otherwise stated. (Per each channel).
Table 5. Power
Symbol Parameter Test conditions Min. Typ. Max. Unit
V
CC
(1)
1. Per device.
Operating supply
voltage
5.5 13 36 V
V
USD
(1)
Undervoltage shutdown 3 4 5.5 V
V
OV
(1)(2)
Overvoltage shutdown 36 V
R
ON
On-state resistance
I
OUT
= 5 A; T
j
=2C 30 mΩ
I
OUT
= 5 A; T
j
= 150 °C 60 mΩ
I
OUT
= 3 A; V
CC
=6V 100 mΩ
V
clamp
Clamp voltage I
CC
=20mA
(2)
2. V
clamp
and V
OV
are correlated. Typical difference is 5 V.
41 48 55 V
I
S
(1)
Supply current
Off-state; V
CC
=13V;
V
IN
=V
OUT
=0V
12 40 µA
Off-state; V
CC
=13V;
V
IN
=V
OUT
=0V; T
j
=2C
12 25 mA
On-state; V
IN
=5V; V
CC
=13V;
I
OUT
= 0 A; R
SENSE
=3.9kΩ
6mA
I
L(off1)
Off-state output current V
IN
=V
OUT
=0V 0 50 µA
I
L(off2)
Off-state output current V
IN
=0V; V
OUT
=3.5V -75 0 µA
I
L(off3)
Off-state output current
V
IN
=V
OUT
=0V;
V
CC
=13V; T
j
=12C
A
I
L(off4)
Off-state output current
V
IN
=V
OUT
=0V; V
CC
=13V;
T
j
=2C
A
Table 6. Protection
(1)
Symbol Parameter Test conditions Min. Typ. Max. Unit
I
lim
DC short circuit current
V
CC
= 13 V 25 40 70 A
5.5 V < V
CC
<36V 70 A
T
TSD
Thermal shutdown
temperature
150 175 200 °C
T
R
Thermal reset temperature 135 °C
T
HYST
Thermal hysteresis 7 15 °C