Datasheet
DocID025077 Rev 2 7/22
VND5N07-E Electrical specifications
21
2.3 Electrical characteristics
T
case
= 25 °C unless otherwise stated.
Table 4. Off
Symbol Parameter Test conditions Min. Typ. Max. Unit
V
CLAMP
Drain-Source clamp
voltage
V
IN
=0V; I
D
= 200 mA 60 70 80 V
V
CLTH
Drain-Source
threshold voltage
V
IN
=0V; I
D
=2mA 55 V
I
ISS
Supply current from
input pin
V
DS
=0V; V
IN
=10V 250 500 µA
V
INCL
Input-Source reverse
clamp voltage
I
IN
= 1 mA -1.0 -0.3 V
I
DSS
Zero input voltage
drain current
(V
IN
=0V)
V
DS
=13V; V
IN
=0V 50 µA
V
DS
=25V; V
IN
= 0 V 200 µA
Table 5. On
(1)
1. Pulsed: pulse duration = 300 µs, duty cycle 1.5%.
Symbol Parameter Test conditions Min. Typ. Max. Unit
R
DS(on)
Static drain-source on
resistance
V
IN
=10 V; I
D
=2.5A 200 mΩ
V
IN
=5V; I
D
=2.5A 280 mΩ
V
IN(th)
Input threshold voltage V
DS
=V
in
; I
D
+ I
in
=1mA 0.8 3 V
Table 6. Dynamic
Symbol Parameter Test conditions Min. Typ. Max. Unit
g
fs
(1)
1. Pulsed: pulse duration = 300µs, duty cycle 1.5%.
Forward
transconductance
V
DS
=13V; I
D
=2.5A 3 4 S
C
OSS
Output capacitance V
DS
=13V; f=1MHz; V
IN
= 0 V 200 300 pF
Table 7. Switching
(1)
Symbol Parameter Test conditions Min. Typ. Max. Unit
t
d(on)
Turn-on delay time
V
DD
=15V; I
D
= 2.5 A;
V
gen
=10V; R
gen
=10Ω
50 100 ns
t
r
Rise time 60 100 ns
t
d(off)
Turn-off delay time 150 300 ns
t
f
Fall time 40 80 ns