Datasheet
ELECTRICAL CHARACTERISTICS (continued)
LOGIC INPUT (Each Channel)
Symbol Parameter Test Conditions Min. Typ. Max. Unit
V
IL
Input Low Level
Voltage
2V
V
IH
Input High Level
Voltage (see note 1)
3.5 V
V
I(hyst.)
Input Hysteresis
Voltage
0.5 V
I
IN
Input Current V
IN
=0to30V
V
IN
=0to2V 25
600 µA
µA
I
LGND
Output Current in
Ground Disconnection
V
CC
=V
INX
=GND=DIAG=24V
T
J
=25
o
C
25 mA
V
ICL
Input Clamp Voltage
(see note 1)
I
IN
=1mA
I
IN
=-1mA
32 36
-0.7
V
V
note 1 : The input voltage is internally clamped at 32V minimum, it is possible to connect the input pins to an higher voltage via an external
resistor calculate to not exceed 10 mA.
PROTECTION AND DIAGNOSTICS
Symbol Parameter Test Conditions Min. Typ. Max. Unit
V
STAT
(•) Status Voltage Output
Low
I
STAT
=5mA
(Fault Condition)
1V
V
SCL
(•) Status Clamp Voltage I
STAT
=1mA
I
STAT
=-1mA
32 36
-0.7
V
V
V
USD
Under Voltage Shut
Down
58V
V
OL
Low State Out Voltage V
IN
=V
ILj
R
LOAD
≥ 10 MΩ 1.5 V
I
LIM
DC Short Circuit
Current
V
CC
=24V R
LOAD
<10mΩ 0.7 2.5 A
I
OVPK
Peak Short Circuit
Current
V
CC
=24V V
in
=30V
R
LOAD
<10mΩ (see figure 2)
4A
I
DIAGH
Leakage on diag pin in
high state
V
DIAG
=24V 100 µA
I
LOAD
Output Leakage
Current
V
CC
=10to36V V
IN
=V
IL
50 µA
t
SC
Delay Time of Current
Limiter
100 µs
T
TSD
Thermal Shut-down
Temperature
150 170
o
C
T
R
Reset Temperature 135 155
o
C
(•) Status determination > 100 µs after the switching edge.
Note: If INPUTn pin is left floating the corresponding channel will automatically switch off. If GND pin is disconnetted, all channels will switch
off provided V
CC
does not exceed 36V
VN330SP