Absolute maximum ratings and operating conditions TS922, TS922A
4/21 Doc ID 5150 Rev 8
Table 2. Operating conditions
Symbol Parameter Value Unit
V
CC
Supply voltage 2.7 to 12 V
V
icm
Common mode input voltage range V
CC-
-0.2 to V
CC+
+0.2 V
T
oper
Operating free air temperature range -40 to +125 °C