Datasheet

T4 Series
3/10
Table 5: Static Characteristics
Table 6: Thermal resistance
Symbol Test Conditions Value Unit
V
T
(2) I
TM
= 5.5 A t
p
= 380 µs T
j
= 25°C
MAX. 1.56 V
V
to
(2)
Threshold voltage
T
j
= 125°C
MAX. 0.89 V
R
d
(2)
Dynamic resistance
T
j
= 125°C
MAX. 120 m
I
DRM
I
RRM
V
DRM
= V
RRM
T
j
= 25°C
MAX.
A
T
j
= 125°C
1mA
Note 1: minimum I
GT
is guaranted at 5% of I
GT
max.
Note 2: for both polarities of A2 referenced to A1.
Symbol Parameter Value Unit
R
th(j-c)
Junction to case (AC)
IPAK / DPAK / TO-220AB 2.6
°C/W
ISOWATT220AB 4.0
R
th(j-a)
Junction to ambient
S = 0.5 cm
²
DPAK 70
°C/W
TO-220AB / ISOWATT220AB 60
IPAK 100
S = Copper surface under tab.