Datasheet

STTH9012TV Characteristics
3/8
Table 4. Dynamic characteristics
Symbol Parameter
Test conditions
Min. Typ Max. Unit
t
rr
Reverse recovery time
I
F
= 1 A, dI
F
/dt = -50 A/µs,
V
R
= 30 V, T
j
= 25° C
125
ns
I
F
= 1 A, dI
F
/dt = -100 A/µs,
V
R
= 30 V, T
j
= 25° C
63 85
I
F
= 1 A, dI
F
/dt = -200 A/µs,
V
R
= 30 V, T
j
= 25° C
50 70
I
RM
Reverse recovery current
I
F
= 45 A, dI
F
/dt = -200 A/µs,
V
R
= 600 V, T
j
= 125° C
32 45 A
S Softness factor
I
F
= 45 A, dI
F
/dt = -200 A/µs,
V
R
= 600 V, T
j
= 125° C
1
t
fr
Forward recovery time
I
F
= 45 A dI
F
/dt = 100 A/µs
V
FR
= 1.5 x V
Fmax
, T
j
= 25° C
700 ns
V
FP
Forward recovery voltage
I
F
= 45 A, dI
F
/dt = 100 A/µs,
T
j
= 25° C
4.5 V
Figure 1. Conduction losses versus
average current
Figure 2. Forward voltage drop versus
forward current
P(W)
0
10
20
30
40
50
60
70
80
90
100
110
0 102030405060
δ=0.05
δ=0.1
δ=0.2
δ=0.5
δ=1
T
δ
=tp/T
tp
I (A)
F(AV)
I (A)
FM
0
20
40
60
80
100
120
140
160
180
200
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0
T
j
= 25 °C
(Maximum values)
T
j
=150°C
(Maximum values)
T
j
=150°C
(Maximum values)
T
j
=150°C
(Typical values)
T
j
=150°C
(Typical values)
V (V)
FM