Datasheet
STTH6012 Characteristics
3/8
Table 4. Dynamic characteristics
Symbol Parameter
Test conditions
Min. Typ Max. Unit
t
rr
Reverse recovery time
I
F
= 1 A, dI
F
/dt = -50 A/µs,
V
R
= 30 V, T
j
= 25° C
125
ns
I
F
= 1 A, dI
F
/dt = -100 A/µs,
V
R
= 30 V, T
j
= 25° C
63 85
I
F
= 1 A, dI
F
/dt = -200 A/µs,
V
R
= 30 V, T
j
= 25° C
50 70
I
RM
Reverse recovery current
I
F
= 60 A, dI
F
/dt = -200 A/µs,
V
R
= 600 V, T
j
= 125° C
32 45 A
S Softness factor
I
F
= 60 A, dI
F
/dt = -200 A/µs,
V
R
= 600 V, T
j
= 125° C
1
t
fr
Forward recovery time
I
F
= 60 A dI
F
/dt = 100 A/µs
V
FR
= 1.5 x V
Fmax
, T
j
= 25° C
750 ns
V
FP
Forward recovery voltage
I
F
= 60 A, dI
F
/dt = 100 A/µs,
T
j
= 25° C
4.5 V
Figure 1. Conduction losses versus
average current
Figure 2. Forward voltage drop versus
forward current
0
20
40
60
80
100
120
140
160
0 1020304050607080
P(W)
T
δ
=tp/T
tp
δ = 0.05
δ = 1
I (A)
F(AV)
δ = 0.1
δ = 0.2
δ = 0.5
0
20
40
60
80
100
120
140
160
180
200
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0
I (A)
FM
V (V)
FM
T = 25°C
(maximum values)
j
T =150°C
(maximum values)
j
T =150°C
(typical values)
j