Datasheet
Symbol Parameter Tests conditions Min. Typ. Max. Unit
I
R
*
Reverse leakage
current
V
R
= 300 V Tj = 25°C
60 µA
Tj = 125°C
60 600
V
F
**
Forward voltage drop I
F
= 30 A Tj = 25°C
1.25 V
Tj = 125°C
0.85 1
Pulse test : * tp = 5 ms, δ < 2 %
** tp = 380 µs, δ < 2%
To evaluate the maximum conduction losses use the following equation:
P = 0.75 x I
F(AV)
+ 0.008 x I
F
2
(RMS)
STATIC ELECTRICAL CHARACTERISTICS (per diode)
Symbol Parameter Value Unit
R
th (j-c)
Junction to case ISOTOP Per diode
Total
1.4
0.75
°C/W
TO-247 Per diode
Total
1
0.55
R
th (c)
Coupling
0.1
When the diodes 1 and 2 are used simultaneously:
∆Tj (diode 1) = P (diode 1) x R
th(j-c)
(per diode) + P (diode 2) x R
th(C)
THERMAL RESISTANCES
Symbol Tests conditions Min. Typ. Max. Unit
trr
I
F
= 0.5 A Irr = 0.25 A I
R
= 1A Tj = 25°C
40 ns
I
F
= 1 A dI
F
/dt = - 50 A/µs V
R
= 30 V
55
tfr
I
F
= 30 A dI
F
/dt = 200 A/µs Tj = 25°C
350 ns
V
FP
V
FR
= 1.1 x V
F
max.
5V
S
factor
Vcc = 200 V I
F
= 30 A Tj = 125°C
0.3 -
I
RM
dI
F
/dt = 200 A/µs
11 A
RECOVERY CHARACTERISTICS
STTH6003TV/CW
2/6