Datasheet
STTH6002C Characteristics
3/9
To evaluate the conduction losses use the following equation:
P = 0.69 x I
F(AV)
+ 0.005 I
F
2
(RMS)
Table 3. Static electrical characteristics
Symbol Parameter Test conditions Typ Max. Unit
I
R
(1)
Reverse leakage current
T
j
= 25° C
V
R
= V
RRM
30
µA
T
j
= 125° C 30 300
V
F
(2)
Forward voltage drop
T
j
= 25° C
I
F
= 30 A 1.05
V
I
F
= 60 A 1.18
T
j
= 150° C
I
F
= 30 A 0.75 0.84
I
F
= 60 A
0.9 0.99
1. Pulse test: t
p
= 5 ms, δ < 2 %
2. Pulse test: t
p
= 380 µs, δ < 2 %
Table 4. Dynamic characteristics
Symbol Parameter
Test conditions
Typ Max. Unit
t
rr
Reverse recovery time
I
F
= 1 A, dI
F
/dt = 200 A/µs,
V
R
= 30 V, T
j
= 25 °C
22 27 ns
I
RM
Reverse recovery current
I
F
= 30 A, dI
F
/dt = 200 A/µs,
V
R
= 160 V, T
j
= 125 °C
7.6 9.5 A
t
fr
Forward recovery time
I
F
= 30 A, dI
F
/dt = 200 A/µs
V
FR
= 1.1 x V
Fmax
, T
j
= 25 °C
220 ns
V
FP
Forward recovery voltage
I
F
= 30 A, dI
F
/dt = 200 A/µs,
T
j
= 25 °C
2.5 V
Figure 1. Peak current versus duty cycle
(per diode)
Figure 2. Forward voltage drop versus
forward current (per diode)
0
20
40
60
80
100
120
140
160
180
200
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
I
M
(A)
T
d
=tp/T
tp
I
M
T
δ
=tp/T
tp
I
M
P = 10 WP = 10 W
P = 5 WP = 5 W
P = 20 WP = 20 W
δ
0
50
100
150
200
250
300
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0
I
FM
(A)
T
j
=25°C
(max values)
T
j
=150°C
(max values)
T
j
=150°C
(typ values)
V
FM
(V)