Datasheet

STTH3L06
2/10
Table 3: Absolute Ratings (limiting values)
Table 4: Thermal Parameters
Table 5: Static Electrical Characteristics
To evaluate the conduction losses use the following equation: P = 0.89 x I
F(AV)
+ 0.055 I
F
2
(RMS)
Table 6: Dynamic Characteristics
Symbol Parameter Value Unit
V
RRM
Repetitive peak reverse voltage 600 V
I
F(RMS)
RMS forward current DO-201AD / SMB / SMC 10 A
DPAK 6
I
F(AV)
Average forward current
δ = 0.5
DO-201AD Tl = 100°C 3 A
DPAK Tl = 155°C
SMB Tl = 80°C
SMC Tl = 100°C
I
FSM
Surge non repetitive forward current DO-201AD tp = 10ms
sinusoidal
70 A
SMB / SMC 60
DPAK 40
T
stg
Storage temperature range -65 to + 175 °C
T
j
Maximum operating junction temperature 175 °C
Symbol Parameter Maximum Unit
R
th(j-l)
Junction to lead DO-201AD L = 10 mm 20 °C/W
DPAK 5.5
SMB 25
SMC 20
R
th(j-a)
Junction to ambient (see fig. 13) DO-201AD L = 10 mm 75 °C/W
Symbol Parameter Test conditions Min. Typ Max. Unit
I
R
Reverse leakage current T
j
= 25°C V
R
= V
RRM
A
T
j
= 150°C 15 100
V
F
Forward voltage drop T
j
= 25°C I
F
= 3A 1.3 V
T
j
= 150°C 0.85 1.05
Symbol Parameter Test conditions Min. Typ Max. Unit
t
rr
Reverse recovery
time
T
j
= 25°C I
F
= 1A dI
F
/dt = -50 A/µs V
R
=30V 60 85 ns
t
fr
Forward recovery
time
T
j
= 25°C I
F
= 3A dI
F
/dt = 100 A/µs
V
FR
= 1.1 x V
Fmax
100 ns
V
FP
Forward recovery
voltage
I
F
= 3A dI
F
/dt = 100 A/µs 7.5 V