Datasheet

Characteristics STTH310
2/7 Doc ID 9346 Rev 3
1 Characteristics
To evaluate the conduction losses use the following equation: P = 1.20 x I
F(AV)
+ 0.075 I
F
2
(RMS)
Table 2. Absolute ratings (limiting values)
Symbol Parameter Value Unit
V
RRM
Repetitive peak reverse voltage 1000 V
I
F(AV)
Average forward current, δ = 0.5
T
L
= 75 °C, δ = 0.5 DO-201AD 3
A
T
L
= 75 °C, δ = 0.5 SMC 3
I
FSM
Forward surge current t
p
= 8.3 ms sinusoidal
DO-201AD 55
A
SMC 45
T
stg
Storage temperature range - 50 to + 175 °C
T
j
Maximum operating junction temperature + 175 °C
Table 3. Thermal parameters
Symbol Parameter Value Unit
R
th(j-l)
Junction to lead
L = 10 mm DO-201AD 20
°C/WSMC 20
R
th(j-a)
Junction to ambient L = 10 mm DO-201AD 75
Table 4. Static electrical characteristics
Symbol Parameter Test conditions Min. Typ. Max. Unit
I
R
Reverse leakage current
T
j
= 25 °C
V
R
= V
RRM
--10
µA
T
j
= 125 °C - - 50
V
F
Forward voltage drop
T
j
= 25 °C
I
F
= 3 A
--1.7
V
T
j
= 150 °C - 0.98 1.42
Table 5. Dynamic electrical characteristics
Symbol Parameter
Test conditions
Min. Typ. Max. Unit
t
rr
Reverse recovery time
I
F
= 0.5 A, I
rr
= 0.25 A
I
R
= 1 A, T
j
= 25 °C
- - 75 ns
t
fr
Forward recovery time
I
F
= 3 A, dI
F
/dt = 50 A/µs
V
FR
= 1.1 x V
Fmax
, T
j
= 25 °C
--300ns
V