Datasheet

Characteristics STTH3010
2/10
1 Characteristics
To evaluate the conduction losses use the following equation:
P = 1.3 x I
F(AV)
+ 0.013 I
F
2
(RMS)
Table 1. Absolute ratings (limiting values at 25° C, unless otherwise specified)
Symbol Parameter Value Unit
V
RRM
Repetitive peak reverse voltage 1000 V
I
F(RMS)
RMS forward current 50 A
I
F(AV)
Average forward current, δ = 0.5
TO-220 / DO-247 T
c
= 105° C
30 A
DOP3I T
c
= 65° C
I
FRM
Repetitive peak forward current t
p
= 5 µs, F = 5 kHz square 300 A
I
FSM
Surge non repetitive forward current t
p
= 10 ms Sinusoidal 180 A
T
stg
Storage temperature range -65 to + 175 °C
T
j
Maximum operating junction temperature 175 °C
Table 2. Thermal parameters
Symbol Parameter Value Unit
R
th(j-c)
Junction to case
TO-220 / DO-247 1.1
°C/W
DOP3I 1.8
Table 3. Static electrical characteristics
Symbol Parameter Test conditions Min. Typ Max. Unit
I
R
(1)
Reverse leakage current
T
j
= 25° C
V
R
= V
RRM
15
µA
T
j
= 125° C 10 100
V
F
(2)
Forward voltage drop
T
j
= 25° C
I
F
= 30 A
2
VT
j
= 100° C 1.4 1.8
T
j
= 150° C 1.3 1.7
1. Pulse test: t
p
= 5 ms, δ < 2 %
2. Pulse test: t
p
= 380 µs, δ < 2 %