Datasheet
STTH1L06 Characteristics
Doc ID 8321 Rev 4 3/9
Table 5. Dynamic characteristics
Symbol Parameter Test conditions Min. Typ. Max. Unit
t
rr
Reverse recovery time T
j
= 25 °C
I
F
= 1 A, dI
F
/dt = -50, A/µs,
V
R
= 30 V
55 80 ns
t
fr
Forward recovery time T
j
= 25 °C
I
F
= 1 A, dI
F
/dt = 100 A/µs
V
FR
= 3.5 V
50 ns
V
FP
Forward recovery
voltage
T
j
= 25 °C I
F
= 1 A, dI
F
/dt = 100 A/µs 10 V
Figure 1. Conduction losses versus
average current
Figure 2. Forward voltage drop versus
forward current
0.00
0.25
0.50
0.75
1.00
1.25
1.50
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 1.3
IF(av)(A)
P(W)
δ = 0.05
δ = 0.1
δ = 0.2
δ = 0.5
δ = 1
T
δ
=tp/T
tp
0.1
1.0
10.0
100.0
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5
VFM(V)
Tj=25°C
(Maximum values)
Tj=150°C
(Maximum values)
Tj=150°C
(Maximum values)
Tj=150°C
(Typical values)
Tj=150°C
(Typical values)
IFM(A)
Figure 3. Relative variation of thermal
impedance junction ambient versus
pulse duration
Figure 4. Relative variation of thermal
impedance junction ambient versus
pulse duration
0.0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
1.E-01 1.E+00 1.E+01 1.E+02 1.E+03
tp(s)
Zth(j-a)/Rth(j-a)
T
δ
=tp/T
tp
δ = 0.5
δ = 0.2
δ = 0.1
Single pulse
DO-41
Lleads = 10mm
epoxy FR4, Lead = 10 mm
0.0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
1.E-
0
1 1.E+
00
1.E+
0
1 1.E+
0
2 1.E+
03
tp(s)
SMB
Zth(j-a)/Rth(j-a)
δ = 0.5
δ = 0.2
δ = 0.1
Single pulse
T
δ
=tp/T
tp
epoxy FR4, S = 1 cm²