Datasheet

Characteristics STTH1L06
2/9 Doc ID 8321 Rev 4
1 Characteristics
To evaluate the conduction losses use the following equation:
P = 0.89 x I
F(AV)
+ 0.165 I
F
2
(RMS)
Table 2. Absolute ratings (limiting values)
Symbol Parameter Value Unit
V
RRM
Repetitive peak reverse voltage 600 V
I
F(RMS)
Forward rms voltage
DO-41 10
A
SMA / SMB 7
I
F(AV)
Average forward current δ = 0.5
DO-41 T
c
= 120 °C
1ASMA T
c
= 135 °C
SMB T
c
= 145 °C
I
FSM
Surge non repetitive forward current
t
p
= 10 ms sinusoidal DO-41
t
p
= 10 ms sinusoidal SMA / SMB
30
20
A
T
stg
Storage temperature range -65 to + 175 °C
T
j
Maximum operating junction temperature 175 °C
Table 3. Thermal parameters
Symbol Parameter Value (max) Unit
R
th(j-l)
Junction to lead
L = 10 mm DO-41 45
°C/W
SMA 30
SMB 25
R
th(j-a)
Junction to ambient
(1)
L = 10 mm DO-41 70
1. Rth(j-a) is measured with a copper area S = 5 cm
2
(see Figure 14.)
Table 4. Static electrical characteristics
Symbol Parameter Test conditions Min. Typ. Max. Unit
I
R
Reverse leakage current
T
j
= 25 °C
V
R
= 600 V
1
µA
T
j
= 150 °C 10 75
V
F
Forward voltage drop
T
j
= 25 °C
I
F
= 1 A
1.3
V
T
j
= 150 °C 0.85 1.05