Datasheet

STTH12R06 Characteristics
Doc ID 7973 Rev 4 3/11
Table 5. Dynamic Characteristics
Symbol Parameter Test conditions Min. Typ. Max. Unit
t
rr
Reverse recovery time T
j
= 25 °C
I
F
= 0.5 A, I
rr
= 0.25 A,
I
R
= 1 A
25
ns
I
F
= 1 A,
dI
F
/dt = -50 A/µs,
V
R
= 30 V
45
I
RM
Reverse recovery current
T
j
= 125 °C
I
F
= 12 A, V
R
= 400 V,
dI
F
/dt = -200 A/µs
7.0 8.4 A
S factor Softness factor 0.2
Q
rr
Reverse recovery charges 180 nC
t
fr
Forward recovery time
T
j
= 25 °C
I
F
= 12 A, dI
F
/dt = 96
A/µs,
V
FR
= 1.1 x V
Fmax
200 ns
V
FP
Forward recovery voltage 5.5 V
Figure 1. Conduction losses versus
average current
Figure 2. Forward voltage drop versus
forward current
0
5
10
15
20
25
30
0123456789101112131415
T
δ
=tp/T
tp
δ = 0.2
δ = 1
δ = 0.05
δ = 0.1
δ = 0.5
P(W)
I (A)
F(AV)
0
10
20
30
40
50
60
70
80
90
100
110
120
0123456
I (A)
FM
V (V)
FM
T =25°C
(maximum values)
j
T =125°C
(maximum values)
j
T =125°C
(typical values)
j
Figure 3. Relative variation of thermal
impedance junction to case versus
pulse duration
Figure 4. Relative variation of thermal
impedance junction to case versus
pulse duration
0.0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
1.E-03 1.E-02 1.E-01 1.E+00
Z/R
th(j-c) th(j-c)
t (s)
p
Single pulse
TO-220AC
TO6220AC Ins
D
2
PAK
0.0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
1.E-03 1.E-02 1.E-01 1.E+00 1.E+01
Z/R
th(j-c) th(j-c)
t (s)
p
Single pulse
TO-220FPAC