Datasheet

STPS60170C
2/6
Table 4: Thermal Parameters
Table 5: Static Electrical Characteristics (per diode)
Pulse test: * tp = 5 ms, δ < 2%
** tp = 380 µs,
δ < 2%
To evaluate the conduction losses use the following equation: P = 0.60 x I
F(AV)
+ 0.053 I
F
2
(RMS)
Symbol Parameter Value Unit
R
th(j-c)
Junction to case
Per diode
Total
1.0
0.7
°C/W
R
th(c)
Coupling
0.4
When the diodes 1 and 2 are used simultaneously:
Tj(diode 1) = P(diode 1) x R
th(j-c)
(Per diode) + P(diode 2) x R
th(c)
Symbol Parameter Tests conditions Min. Typ Max. Unit
I
R
*
Reverse leakage current
T
j
= 25 °C
V
R
= V
RRM
35 µA
T
j
= 125 °C
835 mA
V
F
**
Forward voltage drop
T
j
= 25 °C
I
F
= 30 A
0.94
V
T
j
= 125 °C
0.72 0.76
T
j
= 25 °C
I
F
= 60 A
0.97 1.05
T
j
= 125 °C
0.86 0.92