Datasheet

STPS3L60 Characteristics
Doc ID 7505 Rev 6 3/11
To evaluate the conduction losses use the following equation :
P = 0.44 x I
F(AV)
+ 0.05 x I
F
2
(RMS)
Table 4. Static electrical characteristics
Symbol Parameter Tests Conditions Min. Typ. Max. Unit
I
R
(1)
1. Pulse test :t
p
= 380 µs, δ < 2%
Reverse leakage current
T
j
= 25 °C
V
R
= V
RRM
--150
µA
T
j
= 100 °C
-415
mA
T
j
= 125 °C
-1430
V
F
(1)
Forward voltage drop
T
j
= 25 °C
I
F
= 3 A
--0.62
V
T
j
= 100 °C
-0.530.61
T
j
= 125 °C
-0.510.59
T
j
= 25 °C
I
F
= 6 A
--0.79
T
j
= 100 °C
-0.620.71
T
j
= 125 °C
-0.60.69
Figure 1. Average forward power dissipation
versus average forward current
Figure 2. Average forward current versus
ambient temperature (
δ = 0.5)
(DO-201AD, SMB)
P (W)
F(AV)
0.00
0.25
0.50
0.75
1.00
1.25
1.50
1.75
2.00
2.25
2.50
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0
T
δ
=tp/T
tp
I (A)
F(AV)
δ = 0.05
δ = 0.1
δ = 0.2
δ = 0.5
δ = 1
I (A)
F(AV)
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
0 25 50 75 100 125 150
R =80°C/W
th(j-a)
R=R
th(j-a) th(j-I)
T (°C)