Datasheet

Figure 5. Reverse leakage current versus reverse voltage
applied (typical values)
1.E-05
1.E-04
1.E-03
1.E-02
1.E-01
1.E+00
1.E+01
1.E+02
0 10 20 30 40 50 60 70 80 90 100 110 120
V
R
(V)
I
R
(mA)
T
j
= 150 °C
T
j
= 125 °C
T
j
= 25 °C
T
j
= 100 °C
T
j
= 75 °C
T
j
= 50 °C
Figure 6. Junction capacitance versus reverse voltage
applied (typical values)
10
100
1000
1 10 100
V
R
(V)
C(pF)
F = 1 MHz
V
OSC
= 30 mV
RMS
T
j
= 25 °C
Figure 7. Forward voltage drop versus forward current
1
10
100
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6
V
F
(V)
I
F
(A)
T
j
= 25 °C
(Maximum values)
T
j
= 125 °C
(Maximum values)
T
j
= 125 °C
(Typical values)
STPS20120D
Characteristics (curves)
DS4232 - Rev 2
page 4/9