Datasheet
STB55NF06, STP55NF06, STP55NF06FP Electrical characteristics
Doc ID 7544 Rev 11 5/19
Table 6. Source drain diode
Symbol Parameter Test conditions Min. Typ. Max. Unit
I
SD
I
SDM
(1)
1. Pulse width limited by safe operating area.
Source-drain current
Source-drain current
(pulsed)
-
50
200
A
A
V
SD
(2)
2. Pulsed: Pulse duration = 300 µs, duty cycle 1.5%
Forward on voltage I
SD
= 50 A, V
GS
= 0 - 1.5 V
t
rr
Q
rr
I
RRM
Reverse recovery time
Reverse recovery charge
Reverse recovery current
I
SD
= 50 A,
di/dt = 100 A/µs,
V
DD
= 30 V, T
j
= 150 °C
(see Figure 17)
-
75
170
4.5
ns
nC
A