Datasheet

Electrical ratings
STP16CPC26
4/28
DocID18469 Rev 6
2 Electrical ratings
2.1 Absolute maximum ratings
Stressing the device above the rating listed in the “absolute maximum ratings” table may
cause permanent damage to the device. These are stress ratings only and operation of the
device at these or any other conditions above those indicated in the operating sections of
this specification is not implied. Exposure to absolute maximum rating conditions for
extended periods may affect device reliability.
Table 3: Absolute maximum ratings
Symbol
Parameter
Value
Unit
V
DD
Supply voltage
0 to 7
V
V
O
Output voltage
-0.5 to 20
V
I
O
Output current
90
mA
V
I
Input voltage
-0.4 to V
DD
+0.4
V
I
GND
GND terminal current
1600
mA
ESD
Electrostatic discharge protection HBM human body model
±2
kV
f
CLK
Clock frequency
30
MHz
2.2 Thermal data
Table 4: Thermal data
Symbol
Parameter
Value
Unit
T
A
Operating free-air temperature range
-40 to +125
°C
T
OPR
Operating temperature range
-40 to +150
°C
T
STG
Storage temperature range
-55 to +150
°C
R
thJA
Thermal resistance junction-ambient
(1)
SO-24
60
°C/W
TSSOP24
85
°C/W
TSSOP24
(2)
exposed pad
37.5
°C/W
QSOP-24
72
°C/W
Notes:
(1)
According with JEDEC standard 51-7.
(2)
The exposed pad should be soldered directly to the PCB to realize the thermal benefits.