Datasheet

Electrical characteristics STM8S105x4/6
84/121 DocID14771 Rev 15
10.3.10 I
2
C interface characteristics
Figure 44. Typical application with I
2
C bus and timing diagram
Table 43. I
2
C characteristics
Symbol Parameter
Standard mode I
2
CFast mode I
2
C
(1)
1. f
MASTER
, must be at least 8 MHz to achieve max fast I
2
C speed (400 kHz)
Unit
Min
(2)
2.
Data based on standard I
2
C protocol requirement, not tested in production
Max
(2)
Min
(2)
Max
(2)
t
w(SCLL)
SCL clock low time 4.7 - 1.3 -
µs
t
w(SCLH)
SCL clock high time 4.0 - 0.6 -
t
su(SDA)
SDA setup time 250 - 100 -
ns
t
h(SDA)
SDA data hold time
0
(3)
3.
The maximum hold time of the start condition has only to be met if the interface does not stretch the low
time
-
0
(4)
4.
The device must internally provide a hold time of at least 300 ns for the SDA signal in order to bridge the
undefined region of the falling edge of SCL
900
(3)
t
r(SDA)
t
r(SCL)
SDA and SCL rise time
(V
DD
= 3 to 5.5 V)
- 1000 - 300
t
f(SDA)
t
f(SCL)
SDA and SCL fall time
(V
DD
= 3 to 5.5 V)
- 300 - 300
t
h(STA)
START condition hold time 4.0 - 0.6 -
µs
t
su(STA)
Repeated START condition setup time 4.7 - 0.6 -
t
su(STO)
STOP condition setup time 4.0 - 0.6 -
t
w(STO:STA)
STOP to START condition time
(bus free)
4.7 - 1.3 -
C
b
Capacitive load for each bus line - 400 - 400 pF
06Y9
6&/
67$57
67$57
6723
670
5HSHDWHG
VWDUW


6'$
6&/
N
N
9
''
9
''
,
&EXV
6'$
W
I6'$
W
U6'$
W
VX6'$
W
K6'$
W
VX67$
W
Z67267$
W
VX672
W
I6&/
W
U6&/
W
Z6&//
W
Z6&/+
W
K67$