Datasheet

DocID022265 Rev 6 59/121
STM32F051x4 STM32F051x6 STM32F051x8 Electrical characteristics
90
6.3.6 Wakeup time from low-power mode
The wakeup times given in Table 32 are the latency between the event and the execution of
the first user instruction. The device goes in low-power mode after the WFE (Wait For
Event
) instruction, in the case of a WFI (Wait For Interruption) instruction, 16 CPU cycles
must be added to the following timings due to the interrupt latency in the Cortex M0
architecture.
The SYSCLK clock source setting is
kept unchanged after wakeup from Sleep mode.
During wakeup from Stop or Standby mode, SYSCLK takes the default setting: HSI 8 MHz.
The wakeup source from Sleep and Stop mode is an EXTI line configured in event mode.
Th
e wakeup source from Standby mode is the WKUP1 pin (PA0).
All timings are derived from tests performed under the ambient temperature and supply
vo
ltage conditions summarized in Table 20: General operating conditions.
6.3.7 External clock source characteristics
High-speed external user clock generated from an external source
In bypass mode the HSE oscillator is switched off and the input pin is a standard GPIO.
The external clock signal has to res
pect the I/O characteristics in Section 6.3.14. However,
the recommended clock input waveform
is shown in Figure 15: High-speed external clock
source AC timing diagram.
Table 32. Low-power mode wakeup timings
Symbol Parameter Conditions
Typ @VDD = VDDA
Max Unit
= 2.0 V = 2.4 V = 2.7 V = 3 V = 3.3 V
t
WUSTOP
Wakeup from Stop
mode
Regulator in run
mode
3.23.12.92.92.85
µs
Regulator in low
power mode
7.05.85.24.94.69
t
WUSTANDBY
Wakeup from
Standby mode
- 60.4 55.6 53.5 52 51 -
t
WUSLEEP
Wakeup from Sleep
mode
- 4 SYSCLK cycles -
Table 33. High-speed external user clock characteristics
Symbol Parameter
(1)
Min Typ Max Unit
f
HSE_ext
User external clock source frequency - 8 32 MHz
V
HSEH
OSC_IN input pin high level voltage 0.7 V
DDIOx
-V
DDIOx
V
V
HSEL
OSC_IN input pin low level voltage V
SS
- 0.3 V
DDIOx
t
w(HSEH)
t
w(HSEL)
OSC_IN high or low time 15 - -
ns
t
r(HSE)
t
f(HSE)
OSC_IN rise or fall time - - 20
Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.