Datasheet
DocID022265 Rev 6 51/121
STM32F051x4 STM32F051x6 STM32F051x8 Electrical characteristics
90
I
DD
Supply
current in
Sleep
mode
HSE
bypass,
PLL on
48 MHz 14.0 15.3
(2)
15.3 16.0
(2)
2.8 3.0
(2)
3.0 3.2
(2)
mA
32 MHz 9.5 10.2 10.2 10.7 2.0 2.1 2.1 2.3
24 MHz 7.3 7.8 7.8 8.3 1.5 1.7 1.7 1.9
HSE
bypass,
PLL off
8 MHz 2.6 2.9 2.9 3.0 0.6 0.8 0.8 0.8
1 MHz 0.4 0.6 0.6 0.6 0.2 0.4 0.4 0.4
HSI clock,
PLL on
48 MHz 14.0 15.3 15.3 16.0 3.8 4.0 4.1 4.2
32 MHz 9.5 10.2 10.2 10.7 2.6 2.7 2.8 2.8
24 MHz 7.3 7.8 7.8 8.3 2.0 2.1 2.1 2.1
HSI clock,
PLL off
8 MHz 2.6 2.9 2.9 3.0 0.6 0.8 0.8 0.8
1. Data based on characterization results, not tested in production unless otherwise specified.
2. Data based on characterization results and tested in production (using one common test limit for sum of I
DD
and I
DDA
).
Table 25. Typical and maximum current consumption from V
DD
at 3.6 V (continued)
Symbol Parameter Conditions f
HCLK
All peripherals enabled All peripherals disabled
Unit
Typ
Max @ T
A
(1)
Typ
Max @ T
A
(1)
25 °C 85 °C 105 °C 25 °C 85 °C 105 °C
Table 26. Typical and maximum current consumption from the V
DDA
supply
Symbol Parameter
Conditions
(1)
f
HCLK
V
DDA
=
2.4 V V
DDA
=
3.6 V
Unit
Typ
Max @ T
A
(2)
Typ
Max @ T
A
(2)
25 °C 85 °C 105 °C 25 °C 85 °C 105 °C
I
DDA
Supply
current in
Run or
Sleep
mode,
code
executing
from Flash
memory or
RAM
HSE
bypass,
PLL on
48 MHz 150 170
(3)
178 182
(3)
164 183
(3)
195 198
(3)
µA
32 MHz 104 121 126 128 113 129 135 138
24 MHz 82 96 100 103 88 102 106 108
HSE
bypass,
PLL off
8 MHz 2.0 2.7 3.1 3.3 3.5 3.8 4.1 4.4
1 MHz 2.0 2.7 3.1 3.3 3.5 3.8 4.1 4.4
HSI clock,
PLL on
48 MHz 220 240 248 252 244 263 275 278
32 MHz 174 191 196 198 193 209 215 218
24 MHz 152 167 173 174 168 183 190 192
HSI clock,
PLL off
8 MHz 72 79 82 83 83.5 91 94 95
1. Current consumption from the V
DDA
supply is independent of whether the digital peripherals are enabled or disabled, being
in Run or Sleep mode or executing from Flash memory or RAM. Furthermore, when the PLL is off, I
DDA
is independent of
clock frequencies.
2. Data based on characterization results, not tested in production unless otherwise specified.
3. Data based on characterization results and tested in production (using one common test limit for sum of I
DD
and I
DDA
).
Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.