Datasheet

DS9773 Rev 4 19/93
STM32F030x4/x6/x8/xC Functional overview
24
3.11 Timers and watchdogs
The STM32F030x4/x6/x8/xC devices include up to five general-purpose timers, two basic
timers and one advanced control timer.
Table 5 compares the features of the different timers.
3.11.1 Advanced-control timer (TIM1)
The advanced-control timer (TIM1) can be seen as a three-phase PWM multiplexed on six
channels. It has complementary PWM outputs with programmable inserted dead times. It
can also be seen as a complete general-purpose timer. The four independent channels can
be used for:
Input capture
Output compare
PWM generation (edge or center-aligned modes)
One-pulse mode output
If configured as a standard 16-bit timer, it has the same features as the TIMx timer. If
configured as the 16-bit PWM generator, it has full modulation capability (0-100%).
The counter can be frozen in debug mode.
Many features are shared with those of the standard timers which have the same
architecture. The advanced control timer can therefore work together with the other timers
via the Timer Link feature for synchronization or event chaining.
Table 5. Timer feature comparison
Timer
type
Timer
Counter
resolution
Counter
type
Prescaler
factor
DMA request
generation
Capture/compare
channels
Complementary
outputs
Advanced
control
TIM1 16-bit
Up,
down,
up/down
Any integer
between 1
and 65536
Yes 4 3
General
purpose
TIM3 16-bit
Up,
down,
up/down
Any integer
between 1
and 65536
Yes 4 -
TIM14 16-bit Up
Any integer
between 1
and 65536
No 1 -
TIM15
(1)
16-bit Up
Any integer
between 1
and 65536
Yes 2 1
TIM16,
TIM17
16-bit Up
Any integer
between 1
and 65536
Yes 1 1
Basic
TIM6,
(1)
TIM7
(2)
16-bit Up
Any integer
between 1
and 65536
Yes 0 -
1. Available on STM32F030x8 and STM32F030xC devices only.