Datasheet

3/10
STD30NF06L
ELECTRICAL CHARACTERISTICS (CONTINUED)
SWITCHING ON
SWITCHING OFF
SOURCE DRAIN DIODE
Note: 1. Pulsed: Pulse duration = 300 µs, duty cycle 1.5 %.
2. Pulse width limited by safe operating area.
Symbol Parameter Test Conditions Min. Typ. Max. Unit
t
d(on)
Turn-on Delay Time
V
DD
= 30 V, I
D
= 18 A
R
G
= 4.7 V
GS
= 4.5 V
(see test circuit, Figure 3)
30 ns
t
r
Rise Time 105 ns
Q
g
Q
gs
Q
gd
Total Gate Charge
Gate-Source Charge
Gate-Drain Charge
V
DD
= 48 V, I
D
= 38 A,
V
GS
= 5 V
23
7
10
31 nC
nC
nC
Symbol Parameter Test Conditions Min. Typ. Max. Unit
t
d(off)
t
f
Turn-off-Delay Time
Fall Time
V
DD
= 30 V, I
D
= 18 A,
R
G
=4.7Ω, V
GS
= 4.5 V
(see test circuit, Figure 3)
65
25
ns
ns
Symbol Parameter Test Conditions Min. Typ. Max. Unit
I
SD
Source-drain Current 35 A
I
SDM
(2)
Source-drain Current (pulsed) 140 A
V
SD
(1)
Forward On Voltage
I
SD
= 35 A, V
GS
= 0
1.5 V
t
rr
Q
rr
I
RRM
Reverse Recovery Time
Reverse Recovery Charge
Reverse Recovery Current
I
SD
= 38 A, di/dt = 100 A/µs,
V
DD
= 15 V, T
j
= 150°C
(see test circuit, Figure 5)
70
140
4
ns
nC
A
Normalized Thermal ImpedenceSafe Operating Area