Datasheet
ST6200C/ST6201C/ST6203C
66/100
SUPPLY CURRENT CHARACTERISTICS (Cont’d)
10.4.3 STOP Mode
Notes:
1. Typical data are based on V
DD
=5.0V at T
A
=25°C.
2. All I/O pins in input with pull-up mode (no load), all peripherals in reset state, OSG and LVD disabled, option bytes
programmed to 00H. Data based on characterization results, tested in production at V
DD
max. and f
CPU
max.
3. Maximum STOP consumption for -40°C<Ta<90°C
4. Maximum STOP consumption for -40°C<Ta<125°C
Figure 41. Typical I
DD
in STOP vs Temperature
for OTP devices
Figure 42. Typical I
DD
in STOP vs Temperature
for ROM devices
Symbol Parameter Conditions Typ
1)
Max Unit
I
DD
Supply current in STOP mode
2)
(see Figure 41 & Figure 42)
OTP devices 0.3
10
3)
20
4)
µ
A
ROM devices 0.1
2
3)
20
4)
3456
VDD [V]
0
200
400
600
800
1000
1200
IDD [nA]
Ta=-40°C
Ta=25°C
Ta=95°C
Ta=125°C
3456
VDD [V]
0
500
1000
1500
IDD [nA]
Ta=-40°C
Ta=25°C
Ta=95°C
Ta=125°C
1