Datasheet

SMP100LC Ordering information scheme
Doc ID 7050 Rev 13 9/12
Figure 17. Test circuit 3 for dynamic I
H
parameter
3 Ordering information scheme
Figure 18. Ordering information scheme
TEST PROCEDURE
1/ Adjust the current level at the I value by short circuiting the AK of the D.U.T.
2/ Fire the D.U.T. with a surge current
H
I=
10A, 10/1000µs.
3/ The D.U.T. will come back off-state within 50ms maximum.
PP
This is a GO-NOGO test which allows to confirm the holding current (I ) level in a
functional test circuit.
H
R
V
BAT
= - 48 V
Surge generator
D.U.T
SMP 100 LC - xxx
Trisil surface mount
Repetitive peak pulse current
Capacitance
Voltage
100 = 100 A
LC = Low capacitance
65 = 65 V