Datasheet
Application information SMP100LC
6/12 Doc ID 7050 Rev 13
Figure 11. Test method of the board with fuse and Trisil
These topologies, using SMP100LC from ST and TCP1.25A from Cooper Bussmann, have
been functionally validated with a Trisil glued on the PCB. Following example was performed
with SMP100LC-270 Trisil. For more information, see Application Note AN2064.
Figure 12. Trisil turns on during lightning strike
Test conditions:
2/10 µs + and - 2.5 and 5 kV, 500 A (10 pulses of each polarity), T
amb
= 25 °C
Test result:
Fuse and Trisil OK after test in accordance with GR1089 requirements.
Surge
Generator
Device to be protected
V
Oscilloscope
I surge
Line side
Voltage probe
Current probe
Test board
I surge (100A/div)
V (50V/div)