Datasheet
5 DC and AC parameters
This section summarizes the operating and measurement conditions, as well as the DC and AC characteristics of
the device. The parameters in the following DC and AC characteristic tables are derived from tests performed
under the measurement conditions listed in the relevant tables. Designers should check that the operating
conditions in their projects match the measurement conditions when using the quoted parameters.
Table 11. Operating and AC measurement conditions
Parameter M41T6x
Supply voltage (V
CC
)
1.3 V to 4.4 V
Ambient operating temperature (T
A
)
–40 to 85 °C
Load capacitance (C
L
)
50 pF
Input rise and fall times ≤ 5 ns
Input pulse voltages
0.2 V
CC
to 0.8 V
CC
Input and output timing ref. voltages
0.3 V
CC
to 0.7 V
CC
Note: Output Hi-Z is defined as the point where data is no longer driven.
Figure 22. AC measurement I/O waveform
0.8V
CC
0.2V
CC
0.7V
CC
0.3V
CC
Figure 23. Crystal isolation example
Crystal
XI
XO
GND
Local Grounding Plane
(Layer 2)
Note: Substrate pad should be tied to V
SS
.
M41T62, M41T64, M41T65
DC and AC parameters
DS3840 - Rev 24
page 23/42