Datasheet

DocID12943 Rev 14 27/47
M24M01-R M24M01-DF DC and AC parameters
46
Table 13. DC characteristics (M24M01-DF, device grade 6)
Symbol Parameter
Test conditions (in addition to
those in Table 6)
Min. Max. Unit
I
LI
Input leakage current
(E1, E2, SCL, SDA)
V
IN
= V
SS
or
V
CC
device in Standby mode
2µA
I
LO
Output leakage current
SDA in Hi-Z, external voltage
applied on SDA: V
SS
or
V
CC
2µA
I
CC
Supply current (Read)
V
CC
= 1.7 V, f
c
= 400 kHz - 1 mA
V
CC
= 2.5 V, f
c
=400 kHz - 1 mA
V
CC
= 5.5 V, f
c
=400 kHz - 1.5 mA
f
c
= 1 MHz - 1.5 mA
I
CC0
Supply current (Write) During t
W
-2
(1)
1. Characterized only, not tested in production.
mA
I
CC1
Standby supply current
Device not selected,
V
IN
= V
SS
or
V
CC
, V
CC
= 1.7 V
-3µA
Device not selected,
V
IN
= V
SS
or
V
CC
, V
CC
= 2.5 V
-3µA
Device not selected,
V
IN
= V
SS
or
V
CC
, V
CC
= 5.5 V
-5µA
V
IL
Input low voltage
(Ei, SCL, SDA, WC)
(2)
2. Ei inputs should be tied to VSS (seeSection 2.3).
1.7 V V
CC
< 2.5 V –0.45 0.25 V
CC
V
2.5 V V
CC
< 5.5 V –0.45 0.30 V
CC
V
V
IH
Input high voltage
(Ei, SCL, SDA, WC)
(3)
3. Ei inputs should be tied to Vcc (see Section 2.3).
1.7 V V
CC
< 2.5 V 0.75 V
CC
V
CC
+1 v
2.5 V V
CC
< 5.5 V 0.70 V
CC
V
CC
+1 v
V
OL
Output low voltage
I
OL
= 1.0 mA, V
CC
= 1.7 V - 0.2 V
I
OL
= 2.1 mA, V
CC
= 2.5 V - 0.4 V
I
OL
= 3.0 mA, V
CC
= 5.5 V - 0.4 V