Datasheet

DC and AC parameters M24C64-DF, M24C64-W, M24C64-R, M24C64-F
26/43 Doc ID 16891 Rev 21
Table 13. DC characteristics (M24xxx-W - device grade 3)
Symbo
l
Parameter
Test conditions (in addition to those
in Tabl e 7 and Tabl e 10 )
Min. Max. Unit
I
LI
Input leakage current
(SCL, SDA, E0, E1,
E2)
V
IN
= V
SS
or
V
CC
device in Standby mode
± 2 µA
I
LO
Output leakage
current
SDA in Hi-Z, external voltage applied
on SDA: V
SS
or
V
CC
± 2 µA
I
CC
Supply current (Read) f
c
= 400 kHz 2 mA
I
CC0
Supply current (Write) During t
W
5
(1)
1. Characterized value, not tested in production.
mA
I
CC1
Standby supply
current
Device not selected
(2)
, V
IN
= V
SS
or
V
CC
2. The device is not selected after power-up, after a Read instruction (after the Stop condition), or after the
completion of the internal write cycle t
W
(t
W
is triggered by the correct decoding of a Write instruction).
10 µA
V
IL
Input low voltage
(SCL, SDA, WC)
–0.45 0.3V
CC
V
V
IH
Input high voltage
(SCL, SDA)
0.7V
CC
6.5 V
Input high voltage
(WC, E0, E1, E2)
0.7V
CC
V
CC
+0.6
V
V
OL
Output low voltage
I
OL
= 2.1 mA, V
CC
= 2.5 V or
I
OL
= 3 mA, V
CC
= 5.5 V
0.4 V