Datasheet
LM193, LM293, LM393 Absolute maximum ratings and operating conditions
3/15
2 Absolute maximum ratings and operating conditions
Table 1. Absolute maximum ratings
Symbol Parameter Value Unit
V
CC
Supply voltage ±18 or 36 V
V
id
Differential input voltage ±36 V
V
in
Input voltage -0.3 to +36 V
Output short-circuit to ground
(1)
Infinite
R
thja
Thermal resistance junction to ambient
(2)
SO-8
TSSOP8
DIP8
MiniSO-8
125
120
85
190
°C/W
R
thjc
Thermal resistance junction to case
(2)
SO-8
TSSOP8
DIP8
MiniSO-8
40
37
41
39
°C/W
T
j
Maximum junction temperature 150 °C
T
stg
Storage temperature range -65 to +150 °C
ESD
HBM: human body model
(3)
800
VMM: machine model
(4)
200
CDM: charged device model
(5)
1500
1. Short-circuits from the output to V
CC
+
can cause excessive heating and potential destruction. The maximum output current
is approximately 20 mA independent of the magnitude of V
CC
+
.
2. Short-circuits can cause excessive heating and destructive dissipation. Values are typical.
3. Human body model: A 100 pF capacitor is charged to the specified voltage, then discharged through a 1.5 kΩ resistor
between two pins of the device. This is done for all couples of connected pin combinations while the other pins are floating.
4. Machine model: A 200 pF capacitor is charged to the specified voltage, then discharged directly between two pins of the
device with no external series resistor (internal resistor < 5 Ω). This is done for all couples of connected pin combinations
while the other pins are floating.
5. Charged device model: all pins and the package are charged together to the specified voltage and then discharged directly
to the ground through only one pin. This is done for all pins.
Table 2. Operating conditions
Symbol Parameter Value Unit
V
CC
Supply voltage 2 to 36 V
V
icm
Common mode input voltage range (V
CC
+
= 30V)
(1)
T
amb
= +25°C
T
min
≤ T
amb
≤ T
max
0 to V
CC
+
-1.5
0 to V
CC
+
-2
V
T
oper
Operating free-air temperature range
LM193, LM193A
LM293, LM293A
LM393, LM393A
-55 to +125
-40 to +105
0 to +70
°C
1. The input common-mode voltage of either input signal voltage should not be allowed to go negative by more than 0.3 V.
The high end of the common-mode voltage range is V
CC
+