Datasheet

Mechanical and electrical specifications LIS2DH
14/49 Doc ID 022516 Rev 1
2.4.2 I
2
C - Inter IC control interface
Subject to general operating conditions for Vdd and top.
Figure 4. I
2
C Slave timing diagram
(e)
Table 7. I
2
C slave timing values
Symbol Parameter
I
2
C standard mode
(1)
I
2
C fast mode
(1)
Unit
Min Max Min Max
f
(SCL)
SCL clock frequency 0 100 0 400 kHz
t
w(SCLL)
SCL clock low time 4.7 1.3
µs
t
w(SCLH)
SCL clock high time 4.0 0.6
t
su(SDA)
SDA setup time 250 100 ns
t
h(SDA)
SDA data hold time 0 3.45 0.01 0.9 µs
t
r(SDA)
t
r(SCL)
SDA and SCL rise time 1000
20 + 0.1C
b
(2)
300
ns
t
f(SDA)
t
f(SCL)
SDA and SCL fall time 300
20 + 0.1C
b
(2)
300
t
h(ST)
START condition hold time 4 0.6
µs
t
su(SR)
Repeated START condition
setup time
4.7 0.6
t
su(SP)
STOP condition setup time 4 0.6
t
w(SP:SR)
Bus free time between STOP
and START condition
4.7 1.3
1. Data based on standard I
2
C protocol requirement, not tested in production.
2. Cb = total capacitance of one bus line, in pF.
e. Measurement points are done at 0.2·Vdd_IO and 0.8·Vdd_IO, for both port.
SPC
CS
SDI
SDO
t
su(CS)
t
v(SO)
t
h(SO)
t
h(SI)
t
su(SI)
t
h(CS)
t
dis(SO)
t
c(SPC)
MSB IN
MSB OUT
LSB OUT
LSB IN
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(3)