Datasheet
LIS2DH Mechanical and electrical specifications
Doc ID 022516 Rev 1 11/49
2.2 Temperature sensor characteristics
@ Vdd =2.5 V, T=25 °C unless otherwise noted
(b)
TCOff
Zero-
g level change
vs temperature
Max delta from 25 °C ±0.5 m
g/°C
Vst
Self-test
output change
(5),(6),(7)
FS bit set to 00
X axis; Normal mode
17 360 LSb
FS bit set to 00
Y axis; Normal mode
17 360 LSb
FS bit set to 00
Z axis; Normal mode
17 360 LSb
Top
Operating
temperature range
-40 +85 °C
1. Typical specifications are not guaranteed.
2. Verified by wafer level test and measurement of initial offset and sensitivity.
3. Typical zero-g level offset value after MSL3 preconditioning.
4. Offset can be eliminated by enabling the built-in high pass filter.
5. The sign of “Self-test output change” is defined by CTRL_REG4 ST bit, for all axes.
6.
“Self-test output change” is defined as the absolute value of:
OUTPUT[LSb]
(Self test enabled)
- OUTPUT[LSb]
(Self test disabled)
. 1LSb=4mg at 10bit representation, ±2 g Full-scale
7. After enabling ST, correct data is obtained after two samples (Low power mode / Normal mode) or after eight samples (high
resolution mode).
Table 3. Mechanical characteristics (continued)
Symbol Parameter Test conditions Min. Typ.
(1)
Max. Unit
b. The product is factory calibrated at 2.5 V. Temperature sensor operation is guaranteed in the range 2 V - 3.6 V
Table 4. Temperature sensor characteristics
Symbol Parameter Min. Typ.
(1)
1. Typical specifications are not guaranteed.
Max. Unit
TSDr
Temperature sensor output
change vs temperature
1 digit/°C
(2)
2. 8-bit resolution.
TODR Temperature refresh rate ODR
(3)
3. Refer to Table 28: Data rate configuration.
Hz
Top Operating temperature range -40 +85 °C