Datasheet

Refer to the test circuits, T
J
= 0 to 125 °C, V
I
= 15 V, I
O
= 500 mA, C
I
= 0.33 µF, C
O
= 0.1 µF unless otherwise
specified.
Table 14. Electrical characteristics of L7809C
Symbol Parameter Test conditions Min. Typ. Max. Unit
V
O
Output voltage
T
J
= 25 °C
8.64 9 9.36 V
V
O
Output voltage
I
O
= 5 mA to 1 A, V
I
= 11.5 to 22 V
8.55 9 9.45 V
V
O
Output voltage
I
O
= 1 A, V
I
= 22 to 26 V, T
J
= 25 °C
8.55 9 9.45 V
∆V
O
(1)
Line regulation
V
I
= 11.5 to 26 V, T
J
= 25 °C
180
mV
V
I
= 12 to 18 V, T
J
= 25 °C
90
∆V
O
(1)
Load regulation
I
O
= 5 mA to 1.5 A, T
J
= 25 °C
180
mV
I
O
= 250 to 750 mA, T
J
= 25 °C
90
I
d
Quiescent current
T
J
= 25 °C
8 mA
∆I
d
Quiescent current change
I
O
= 5 mA to 1 A
0.5
mA
V
I
= 11.5 to 26 V
1
∆V
O
/∆T
Output voltage drift
I
O
= 5 mA
-1 mV/°C
eN Output noise voltage
B = 10 Hz to 100 kHz, T
J
= 25 °C
70
µV/V
O
SVR Supply voltage rejection
V
I
= 12 to 23 V, f = 120 Hz
55 dB
V
d
Dropout voltage
I
O
= 1 A, T
J
= 25 °C
2 V
R
O
Output resistance f = 1 kHz 17 mΩ
I
sc
Short circuit current
V
I
= 35 V, T
J
= 25 °C
0.40 A
I
scp
Short circuit peak current
T
J
= 25 °C
2.2 A
1. Load and line regulation are specified at constant junction temperature. Changes in V
O
due to heating
effects must be taken into account separately. Pulse testing with low duty cycle is used.
Note: Minimum load current for regulation is 5 mA.
L78
Electrical characteristics
DS0422 - Rev 36
page 17/55
Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.