Datasheet

Table Of Contents
Programming manual L6470
54/73 DocID16737 Rev 7
Any attempt to write the CONFIG register when the motor is running causes the command
to be ignored and the NOTPERF_CMD flag to rise (see Section 9.1.22).
Table 32. Available PWM frequencies [kHz]: 24-MHz oscillator frequency
F_PWM_DEC
F_PWM_INT 000 001 010 011 100 101 110 111
000 29.3 35.2 41.0 46.9 58.6 70.3 82.0 93.8
001 14.6 17.6 20.5 23.4 29.3 35.2 41.0 46.9
010 9.8 11.7 13.7 15.6 19.5 23.4 27.3 31.3
011 7.3 8.8 10.3 11.7 14.6 17.6 20.5 23.4
100 5.9 7.0 8.2 9.4 11.7 14.1 16.4 18.8
101 4.9 5.9 6.8 7.8 9.8 11.7 13.7 15.6
110 4.2 5.0 5.9 6.7 8.4 10.0 11.7 13.4
Table 33. Available PWM frequencies [kHz]: 32-MHz oscillator frequency
F_PWM_DEC
F_PWM_INT 000 001 010 011 100 101 110 111
000 39.1 46.9 54.7 62.5 78.1 93.8 109.4 125.0
001 19.5 23.4 27.3 31.3 39.1 46.9 54.7 62.5
010 13.0 15.6 18.2 20.8 26.0 31.3 36.5 41.7
011 9.8 11.7 13.7 15.6 19.5 23.4 27.3 31.3
100 7.8 9.4 10.9 12.5 15.6 18.8 21.9 25.0
101 6.5 7.8 9.1 10.4 13.0 15.6 18.2 20.8
110 5.6 6.7 7.8 8.9 11.2 13.4 15.6 17.9