Datasheet

Table Of Contents
DocID16737 Rev 7 51/73
L6470 Programming manual
73
The SW_MODE bit sets the external switch to act as HardStop interrupt or not:
The OC_SD bit sets whether an overcurrent event causes or not the bridges to turn off; the
OCD flag in the STATUS register is forced low anyway:
The POW_SR bits set the slew rate value of power bridge output:
The EN_VSCOMP bit sets whether the motor supply voltage compensation is enabled or
not.
Table 24. External switch hard stop interrupt mode
SW_MODE Switch mode
0 HardStop interrupt
1 User disposal
Table 25. Overcurrent event
OC_SD Overcurrent event
1 Bridges shut down
0 Bridges do not shut down
Table 26. Programmable power bridge output slew rate values
POW_SR
[1 .… 0]
Output slew rate
(1)
[V/µs]
1. See S
Rout_r
and S
Rout_f
parameters in Table 5 on page 11 for details.
00 320
01 75
10 110
11 260
Table 27. Motor supply voltage compensation enable
EN_VSCOMP Motor supply voltage compensation
0 Disabled
1 Enabled