22/73 DocID16737 Rev 7
Figure 5. Charge pump circuitry
6.4 Microstepping
The driver is able to divide the single step into up to 128 microsteps. Stepping mode can be
programmed by the STEP_SEL parameter in the STEP_MODE register (see Table 18 on
page 48).
Step mode can only be changed when bridges are disabled. Every time the step mode is
changed the electrical position (i.e. the point of microstepping sinewave that is generated) is
reset to zero and the absolute position counter value (see Section 6.5) becomes
meaningless.
Figure 6. Normal mode and microstepping (128 microsteps)