Datasheet

BTA16, BTB16 and T16 Series
3/9
■ Standard (4 quadrants)
Table 5: Static Characteristics
Table 6: Thermal resistance
Symbol Test Conditions Quadrant
BTA16 / BTB16
Unit
CB
I
GT
(1)
V
D
= 12 V R
L
= 33 Ω
I - II - III
IV
MAX.
25
50
50
100
mA
V
GT
ALL MAX. 1.3 V
V
GD
V
D
= V
DRM
R
L
= 3.3 kΩ T
j
= 125°C
ALL MIN. 0.2 V
I
H
(2) I
T
= 500 mA
MAX. 25 50 mA
I
L
I
G
= 1.2 I
GT
I - III - IV
MAX.
40 60
mA
II 80 120
dV/dt (2)
V
D
= 67 %V
DRM
gate open T
j
= 125°C
MIN. 200 400 V/µs
(dV/dt)c (2) (dI/dt)c = 7 A/ms
T
j
= 125°C
MIN. 5 10 V/µs
Symbol Test Conditions Value Unit
V
T
(2) I
TM
= 22.5 A t
p
= 380 µs T
j
= 25°C
MAX. 1.55 V
V
to
(2)
Threshold voltage
T
j
= 125°C
MAX. 0.85 V
R
d
(2)
Dynamic resistance
T
j
= 125°C
MAX. 25 mΩ
I
DRM
I
RRM
V
DRM
= V
RRM
T
j
= 25°C
MAX.
5µA
T
j
= 125°C
2mA
Note 1: minimum I
GT
is guaranted at 5% of I
GT
max.
Note 2: for both polarities of A2 referenced to A1.
Symbol Parameter Value Unit
R
th(j-c)
Junction to case (AC)
D
2
PAK / TO-220AB
1.2
°C/W
TO-220AB Insulated 2.1
R
th(j-a)
Junction to ambient
S = 1 cm
²
D
2
PAK
45
°C/W
TO-220AB / TO-220AB Insulated 60
S = Copper surface under tab.